TIME2110 Ultrasonic Thickness Gauge
1. Performance Metrics
Display mode: Four-digit LCD display
Operating temperature range: 0 °C~ 40 °C
Power supply: two batteries 7 No. dry battery
Power consumption: Operating current < 20mA (3V)
Weight: approximately 140g
2. Main Features
● Features both metric and imperial display modes
● Automatic zero-point calibration, enabling correction of systematic errors.
● Linear automatic compensation: Throughout the entire measurement range, computer software is used to correct probe nonlinear errors, thereby enhancing accuracy.
● The up and down adjustment keys allow for quick fine-tuning of sound velocity and thickness, and enable rapid access to the thickness storage units.
● Coupling status indication: A coupling indicator is provided; by observing its stable state, one can determine whether the coupling is functioning properly.
● It can store ten thickness values, and the data is retained even after power-off, providing convenience for high-altitude and field operations.
● Sound Velocity Measurement Function: Directly measures the sound velocity based on the sample thickness, eliminating the need for table lookups or manual conversions.
● Can store the sound velocities of five different materials.
● Low-voltage warning.
● Auto Shut-Off: The timed auto shut-off feature helps you cut the power.
● Fully sealed operation with a membrane for all connections ---- Oil-resistant, extending service life.
|
|
TIME2110 |
|
|
Display resolution /(mm) |
0.1 |
|
|
Adjustable speed of sound |
√ |
|
|
Sound speed adjustment range /(m/s) |
1000 ~ 9999 |
|
|
Indication error (steel) /(mm) |
± (0.1+1%H) |
|
|
Repeatability /(mm) |
0.1 |
|
|
Indication stability /(mm) |
0.1 |
|
|
Indication error of curved-surface measurement (steel) /(mm) |
F 20mm × 3.0mm,(5P F 10 Probe, 5P F 10/900 Probe ) , F 15mm × 2.0mm(7P F 6 Probe ), The indication error shall not exceed ± 0.1。 |
|
|
Thickness indication error with varying sound velocity (steel) /(mm) |
Not greater than ± (0.2+nH/100) 。 |
|
|
Sound Speed Measurement /(m/s) |
H ≤ 20mm At that time, the measurement error does not exceed ± 1mm/H × 100%; H > 20mm At that time, the measurement error does not exceed ± 5%。 |
|
|
Voltage Variation Stability (Steel) /(mm) |
0.1 |
|
|
Undervoltage indication |
After the thickness gauge is turned on, when the battery voltage is 2.2V ± 0.2 V At that time, the screen displayed “ BATT ”。 |
|
|
5P F 10 5P F 10/90 ° |
Measurement range (steel) /(mm) |
1.2 ~ 225.0 |
|
7P F 6 |
Measurement range (steel) /(mm) |
0.75 ~ 60.0 |
|
SZ2.5P |
Measurement range (steel) /(mm) |
3.0 ~ 300.0 |