Welcome to the official website of Shanghai Shangcai Testing Machine Co., Ltd.!
560RSSZ Automatic All-Rockwell Hardness Tester

1. Integrated cast-aluminum structure with dual sensors
2. One-touch operation directly displays the measurement results.
3. The touchscreen provides real-time dynamic display of the operating process.

Suitable for quenched, tempered, annealed, and cold‑hard castings, malleable castings, cemented carbide steels, aluminum alloys, copper alloys, and bearings.
Hardness testing of steel and similar materials. Also applicable to surface‑hardened steels, as well as the surface heat‑treated and chemically treated layers of materials, and to copper and aluminum alloys, including thin sections.
Sheet metal, galvanized materials, chrome-plated materials, tin-plated materials, bearing steel, chilled cast iron, and others.


The 560RSSZ automatic Rockwell hardness tester features a modern design, comprehensive functionality, user-friendly operation, clear and intuitive display, and stable performance; it is a high-tech product integrating mechanical and electrical components. The instrument has eliminated the use of weights and instead employs Closed-loop sensor-controlled loading , It can perform hardness tests across the full range of Rockwell and superficial Rockwell scales, with one‑button operation and fully automated testing.
1. The integrated cast-aluminum structure will Airframe body Rigidity reaches 99%, with minimal deformation;
2. Structural Implementation The 1:1 high-precision gravity-sensing system, combined with zero-backlash ball screws for force control, ensures that each loading operation is accurate and error-free.
3. Force sensor: Imported from a U.S. brand, with repeatability reaching ±0.05%;
4. After heat treatment, the screw rod achieves a hardness of With a hardness ranging from 35 to 40 HRC, the lead screw ensures stable measurement data across different lifting heights. Through heat treatment and a wire‑drawing process, the lead screw is robust and wear‑resistant, significantly reducing the likelihood of clearance caused by long‑term wear that could compromise measurement stability.
5. Installation of the indenter assembly LED light source, enabling clear observation of the testing process;
6.8-inch HD touchscreen display and operation, equipped with dynamic graphs to monitor in real time the operating status of the force sensor and displacement sensor, with synchronous display of test depth.
7. The equipment supports the selection of all Rockwell and superficial Rockwell hardness scales, enables conversion among various hardness scales, and features arc‑correction compensation.
8. Jog the worktable to achieve rapid upward or downward movement;
9. With a single button, the specimen is raised, the indenter applies load, holds the load, and releases it; the hardness value is displayed, and the test table returns to its initial position.
10. Equipped with data storage, automatic calculation of maximum, minimum, average values, standard deviation, repeatability, etc.; test results can be selectively deleted; supports print output; and features… The USB interface can export Excel files, and it is equipped with an RS-232 interface for connecting to a computer for output.

|
Model number |
560RSSZ |
|
Initial test force |
3kgf (29.42N), 10kgf (98.07N) |
|
Total test force |
15kgf (147.1N), 30kgf (294.2N), 45kgf (441.3N), 60 kgf (588.4 N), 100 kgf (980.7 N), 150 kgf (1471 N) |
|
Indenter specifications |
Diamond Rockwell indenter, φ1.588 mm ball indenter |
|
Method of Applying Test Force |
Automatic (Load/Keep Charge/Unload) |
|
Operating method |
Automatic lifting and return-to-home, completed with a single button press. |
|
Hardness reading |
Hardness values are obtained via a digital display touchscreen. |
|
Measuring scale |
HRA, HRD, HRC, HRFW, HRBW, HRGW, HRHW, HREW, HRKW, HRL, HRM, HRP, HRR, HRS, HRV HR15N, HR30N, HR45N, HR15TW, HR30TW, HR45TW, HR15W, HR30W, HR45W, HR15X, HR30X, HR45X, HR15Y, HR30Y, HR45Y |
|
Convert Ruler |
HV, HK, HRA, HRBW, HRC, HRD, HREW, HRFW, HRGW, HRKW, HR15N, HR30N, HR45N, HR15TW, HR30TW, HR45TW, HBW |
|
Data Output |
Built-in printer, USB interface |
|
Hardness value resolution |
0.1HR |
|
Shelf life |
0~99s |
|
Maximum specimen height |
310mm |
|
Distance from the center of the indenter to the machine wall |
150mm |
|
Power supply |
AC 220V, 50Hz |
|
Implementation Standard |
ISO 6508, ASTM E18, JIS Z2245, GB/T 230.2 |
|
External dimensions |
535×330×890mm, outer carton dimensions 820×460×1170mm |
|
Weight |
Net weight 80 kg, gross weight 100 kg |

|
Name |
Quantity |
Name |
Quantity |
|
Instrument host |
1 unit |
Diamond Rockwell indenter |
1 piece |
|
f1.588mm ball indenter |
1 piece |
Φ150mm flat test bench |
1 piece |
|
Φ74mm flat test bench |
1 piece |
Φ40mm V-shaped test stand |
1 piece |
|
Standard hardness block 60–70 HRC |
1 piece |
Standard hardness block 20–30 HRC |
1 piece |
|
Standard hardness block 80–100 HRBW |
1 piece |
Standard hardness block 70–85 HR30TW |
1 piece |
|
Standard hardness block 65–80 HR30N |
1 piece |
2A fuse |
2 pieces |
|
Hex key wrench |
1 piece |
Wrench |
1 piece |
|
Power cord |
1 piece |
Dust cover |
1 piece |
|
Certificate of Conformity |
1 serving |
Product Manual |
1 serving |