Welcome to the official website of Shanghai Shangcai Testing Machine Co., Ltd.!
QHVT-10Z/50Z Digital Display Vickers Hardness Tester

1. Featuring a brand-new aluminum alloy die-casting process, it delivers robust stability and a sleek, modern aesthetic.
2. Direct-drive motor for vertical loading, providing more stable force values.
3. Special-material lifting shaft, with a more stable structural design.
4. The turret rotates faster, resulting in higher testing efficiency.

Ferrous metals, nonferrous metals, IC wafers, surface coatings, laminated metals; glass, ceramics, agate, gemstones, thin plastics, etc.; carburized layers
and hardness testing of the depth and gradient of the quenched hardened layer.

QHVT-10Z/50Z Direct-Drive Digital Display Vickers hardness tester Employing a state-of-the-art aluminum alloy die-casting process, the housing is robust and stable, with a sleek, modern aesthetic. It features a direct-drive loading mechanism that ensures consistent force application and high testing efficiency. Equipped with a digital micrometer eyepiece, the device displays test force, indentation length, dwell time, scale conversion, and elapsed time clearly on the touchscreen. During operation, simply measure the indentation and press the eyepiece button to automatically calculate the hardness value and display it on the screen.
- Employing a cutting-edge aluminum alloy die-casting process, the housing is robust and stable, with a sleek and stylish design.
- It employs a lifting lead screw made of a special material, with hardness achieved through heat treatment. Achieve Between 35 HRC and 40 HRC , wear-resistant; the worm gear and worm screw design ensures smoother lifting.
- It employs a closed-loop sensor‑based loading control system, with direct motor‑driven vertical force application, resulting in more stable force values.
- The turret operates at higher speeds, resulting in greater testing efficiency.
- The unit features a modular enclosure, making maintenance and servicing more convenient.
- possessing Three objective lenses are used for measurement, with automatic identification and switching between the objectives and the indenter. ;
- Adopt LED cold light source, offering greater durability;
- 8-inch HD color touchscreen with adjustable tilt for more user-friendly operation;
- It features Vickers and Knoop test modes, supports conversion among various hardness scales, and enables real-time conversion with instant selection and switching.
- Supports upper and lower limit settings, with alerts for out-of-range conditions.
- Hardness Test Results Real-time saving, data categorization, optional deletion, automatic calculation of maximum, minimum, and average values, and equipped with… The RS232 interface is provided for users to connect to a computer for output.

|
Model number |
QHVT-10Z |
QHVT-50Z |
|
|
Test force |
kgf |
0.3kgf, 0.5kgf, 1kgf, 2kgf, 2.5kgf, 3kgf, 5kgf, 10kgf |
0.5kgf, 1kgf, 2kgf, 2.5kgf, 3kgf, 5kgf, 10kgf, 20kgf, 30kgf, 50kgf |
|
N |
2.94N, 4.90N, 9.80N, 19.6N, 24.5N, 29.4N, 49N, 98N |
4.90 N, 9.80 N, 19.6N, 24.5N, 29.4N, 49N, 98 N, 196N, 294N, 490N |
|
|
Test mode |
HV/HK |
||
|
Hardness test range |
1HV~ 3000 HV |
||
|
Hardness value resolution |
0.1 HV |
||
|
Method of Applying Test Force |
Automatic (loading) /Protect Load/Unload) |
||
|
Objective and indenter switching |
Automatic switching |
||
|
Data Output |
RS232 interface |
||
|
Hardness reading |
8-inch color touchscreen, with automatic data storage. |
||
|
Convert Ruler |
HRA, HRB W , HRC, HRD, HRE W , HRF W , HRG W , HR Hardware , HRK W , HR15N, HR30N, HR45N, HR15T W , HR30T W , HR45T W , HV, HK, HS, HBS, HB W, HLD real-time conversion, instant selection and switching |
||
|
Data Statistics |
It can store six sets of folders, each set… 1,000 data points; automatically calculates the maximum, minimum, and average values, with optional statistical aggregation and output. |
||
|
Accessibility |
Upper and lower limit settings, out-of-tolerance alert |
||
|
Eyepiece |
10 × Digital Display Micrometer Eyepiece |
||
|
Objective lens |
10 × ,20 × ,40 × |
||
|
Total magnification |
100 × ,200 × ,400 × |
||
|
Effective field of view |
10 × :800 mu m, 20 × :400 mu m, 40 × :200 mu m |
||
|
Minimum graduation of the micrometer drum |
10 × :0.25 mu m, 20 × :0.13 mu m, 40 × :0.06 mu m |
||
|
Shelf life |
0~99s |
||
|
Light source |
LED cold light source |
||
|
Digital display X-Y test platform |
Size : 1 20 ×1 20 mm; Stroke: 25×25 mm; Resolution: 0.00 1 mm |
||
|
Maximum specimen height |
175 mm |
||
|
Distance from the center of the indenter to the machine wall |
140 mm |
||
|
Power supply |
AC220V,50Hz |
||
|
Implementation Standard |
GB/T 4340, ISO 650 7, ASTM E92, JIS Z224 4 |
||
|
External dimensions |
495 × 575 × 670 mm |
||
|
Net weight |
35k g |
||

|
Name |
Quantity |
Name |
Quantity |
|
Instrument host |
1 unit |
Attachment Box |
1 piece |
|
10 × Digital Display Micrometer Eyepiece |
1 piece |
Digital Display Cross-Table |
1 piece |
|
Standard Vickers hardness block |
2 pieces |
Leveling screw |
4 pieces |
|
Level gauge |
1 piece |
Hex key wrench 2.5mm, 3mm |
Each 1 piece |
|
Screwdriver |
2 pieces |
Fuse 1 A |
2 pieces |
|
Power cord |
1 piece |
Dust cover |
1 piece |
|
Product Manual |
1 serving |
Certificate of Conformity |
1 serving |
Related products