Time TIME2500 Magnetic Coating Thickness Gauge
Product Overview:
This instrument is an ultra‑compact measuring device that enables rapid, nondestructive, and highly accurate measurement of the thickness of nonmagnetic coatings on magnetic metal substrates. It is widely applicable in manufacturing, metalworking, the chemical industry, commodity inspection, and other testing fields. Thanks to its compact size and the integration of the probe with the main unit, it is particularly well suited for on‑site measurements at engineering locations.
TT220 An alternative product that delivers more accurate measurements, faster results, and greater ease of use.
This instrument complies with the following relevant standards:
GB/T 4956-2003 Measurement of Non-Magnetic Coating Thickness on a Magnetic Substrate—Magnetic Method
Features:
♦ Zero-point and two-point calibration are available, and the probe’s systematic error can be corrected using the basic calibration method.
♦ It features two measurement modes: continuous measurement and single-shot measurement.
♦ It features two operating modes: direct mode and batch mode;
♦ Storage 500 a measured value;
♦ Equipped with a delete function: allows deletion of the current value, calibration value, limit value, and all values;
♦ There are five statistical measures: the mean ( MEAN ), maximum value ( MAX ) , minimum value ( MIN ), number of tests ( NO .), standard deviation ( S.DEV );
♦ Equipped with a printing function, it can print measured values and statistical data.
♦ Features undervoltage indication;
♦ The operation process is accompanied by an audible beep.
♦ Features error prompting;
♦ Chinese and English menus;
♦ Backlit display;
♦ Automatic and manual shutdown.
Technical Specifications:
|
Probe type |
F |
|
|
Measurement principle |
Magnetic induction |
|
|
Measurement range |
0-1250µm |
|
|
Minimum display resolution |
0.1µm (100µm The following is 0.1µm) |
|
|
Probe connection method |
Integration |
|
|
Indication error |
Zero calibration (one) |
±[ 3% H + 1 ] |
|
Two-point calibration (one) |
±[ (1% ~ 3%) H + 1 ] |
|
|
Measurement conditions |
Minimum radius of curvature (mm) |
Convex 1.5 ; concave 9 |
|
Diameter of the minimum area of the matrix (mm) |
f 7 |
|
|
Minimum critical thickness (mm) |
0.5 |
|
|
Temperature and humidity |
0 ~ 40 °C; 20%RH ~ 90%RH |
|
|
Statistical functions |
Average ( MEAN ), maximum value ( MAX ), minimum value ( MIN ), |
|
|
Work style |
Direct method (DIRECT) And grouping method (Appl) |
|
|
Measurement method |
Continuous measurement mode ( CONTINUE ) and the single-measurement mode ( SINGLE ) |
|
|
Storage capacity |
Storage 500 a measured value |
|
|
Print / Connect the computer |
Optional printer / Unable to connect to the computer. |
|
|
Shutdown method |
Two modes: automatic and manual. |
|
|
Power supply |
AAA Type 1.5V ( 7 No.) Dry battery 2 Festival |
|
|
External dimensions |
146 × 60 × 28mm |
|
|
Weight |
132g |
|
Basic configuration:
TIME2500 Host 1 Tai; Standard Sample 1 Set; standard matrix 1 block
Optional accessories:
TA230 Printer; communication cable