XHRS-150 Digital Display Plastic Rockwell Hardness Tester

- The monolithic cast-iron structure achieves 99% body‑shell rigidity, minimizing deformation, while the housing undergoes more than six months of natural aging to ensure stable physical properties. ;
- Lifting screw rod After heat treatment, the hardness reaches Between 35 and 40 HRC, Structurally stable and wear-resistant;
- The weights and lever are calibrated using traditional manufacturing techniques, ensuring high accuracy and allowing for fine adjustments via the mechanical structure.
- 5.6-inch HD touchscreen display and operation, with dynamic image visualization of the equipment’s operating process and audible buzzer alerts;
- Supports Rockwell and Plastic Rockwell hardness scales; after selecting a scale, the system prompts the appropriate indenter and test force, with the test force adjusted via the load‑change handwheel.
- Supports conversion among various hardness scales, with real-time conversion and instant switching.
- Supports upper and lower limit settings, provides over‑tolerance alarm notifications, and features arc‑correction compensation.
- Hardness Test Results Real-time saving, automatic calculation of maximum, minimum, average, standard deviation, repeatability, and other parameters; supports multi‑folder selection, with options to delete files and print output.
- Built-in thermal printer with fast printing speed, equipped with USB interface allows users to directly export data to a USB flash drive. 。

Hard plastics, hard rubber, aluminum, tin, copper, mild steel, synthetic resins, and friction materials.

X HRS-150 Digital Display Plastic Rockwell hardness tester It features a high-definition color touchscreen, It can display and set the current test scale, test force, indenter, dwell time, hardness conversion values, and other parameters. The instrument employs a weight‑loading mechanism; during operation, simply apply a manual pre‑load until the instrument emits an audible beep, after which it automatically applies the load, holds it, unloads, and displays the hardness value. The procedure is user‑friendly, with intuitive readouts. 。
- The monolithic cast-iron structure achieves 99% body‑shell rigidity, minimizing deformation, while the housing undergoes more than six months of natural aging to ensure stable physical properties. ;
- Lifting screw rod After heat treatment, the hardness reaches Between 35 and 40 HRC, Structurally stable and wear-resistant;
- The weights and lever are calibrated using traditional manufacturing techniques, ensuring high accuracy and allowing for fine adjustments via the mechanical structure.
- 5.6-inch HD touchscreen display and operation, with dynamic image visualization of the equipment’s operating process and audible buzzer alerts;
- Supports Rockwell and Plastic Rockwell hardness scales; after selecting a scale, the system prompts the appropriate indenter and test force, with the test force adjusted via the load‑change handwheel.
- Supports conversion among various hardness scales, with real-time conversion and instant switching.
- Supports upper and lower limit settings, provides over‑tolerance alarm prompts, and features arc‑correction compensation.
- Hardness Test Results Real-time saving, automatic calculation of maximum, minimum, average, standard deviation, repeatability, and other parameters; supports multi‑folder selection, with options to delete files and print output.
- Built-in thermal printer with fast printing speed, equipped with USB interface allows users to directly export data to a USB flash drive. 。

|
Model number |
X HRS-150 |
|
Initial test force |
10 k gf (98.07N) |
|
Total test force |
60 k gf ( 58 8.4N), 100 k gf (980.7N), 150 k gf (1471N) |
|
Indenter specifications |
3.175 mm, 6.35 mm, 12.7 mm tungsten carbide alloy ball indenter |
|
Method of Applying Test Force |
Automatic (loading) /Protect Load/Unload) |
|
Hardness reading |
5.6-inch touchscreen Obtain the hardness value |
|
Test Ruler |
HRA , HRD, HRC, HRFW, HRBW, HRGW, HRHW, HREW, HRKW, HRL, HRM, HRP, HRR, HRS, HRV |
|
Convert Ruler |
HV, HK, HRA , HRB W, HRC, HRD , HREW, HRFW, HRG W, HRKW, HR15N, HR30N, HR45N, HR15TW, HR30TW, HR45TW, HS, HBW – real-time conversion, select and switch instantly. |
|
Data Statistics |
It can store six sets of folders, each set… 1,000 data points—automatically calculate the maximum, minimum, average, total, standard deviation, and repeatability; selective statistical analysis and output are also supported. |
|
Data Output |
Built-in printer, USB Interface |
|
Accessibility |
Upper and lower limit settings, with over‑tolerance alarm prompts; Curved-surface correction: automatically corrects measurement results for cylindrical and spherical surfaces. |
|
Hardness value Resolution |
0.1HR |
|
Shelf life |
0–99 s; the initial test force holding time can be set. Total test force holding time and elastic recovery holding time |
|
Maximum specimen height |
185mm |
|
Distance from the center of the indenter to the machine wall |
165mm |
|
Power supply |
AC 220V, 50Hz |
|
Implementation Standard |
GB/T 230 , ISO 6508, ASTM E18, JIS Z2245 |
|
External dimensions |
520×215×700mm |
|
Net weight |
78kg |

|
Name |
Quantity |
Name |
Quantity |
|
Instrument host |
1 unit |
Tungsten carbide alloy ball indenter, diameters: 3.175 mm, 6.35 mm, 12.7 mm |
One of each |
|
Φ150mm flat test bench |
1 piece |
Φ74mm flat test bench |
1 piece |
| Φ40mm V-shaped test stand |
1 piece |
Weights A, B, C |
One each |
|
Standard hardness block 75–85 HREW |
1 piece |
Standard hardness block 110–120 HRL |
1 piece |
|
Standard hardness block 100–110 HRM |
1 piece |
Standard hardness block 115–125 HRR |
1 piece |
|
2A fuse |
2 pieces |
Power cord |
1 piece |
|
Leveling screw |
4 pieces |
Level gauge |
1 piece |
|
Wrench |
1 piece |
Hex key wrench |
1 piece |
|
Certificate of Conformity |
1 serving |
Dust cover |
1 piece |
|
Printer manual |
1 serving |
Product Manual |
1 serving |